TC-5570A mmWave Shield Box Key Features
- Specifically designed for Millimeter wave test
- Reliable High RF Shielding from 26 GHz to 67 GHz
- EMI filters on all Data ports
- Easy Opening/Closing of Door
- Customizable Data connections
*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Typical RF Shielding
Typical RF Shielding
The shielding effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
Frequency |
Shielding effectiveness (dB) |
26 to 40 GHz |
> 60 dB |
40 to 50 GHz |
> 60 dB |
50 to 67 GHz |
> 60 dB |
Custom Configurations
TC Manual RF Shield Box Custom I/O Interface Panel
Customized I/O Interface panels are available. Please contact the CTS sales team for more information
*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
- Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
- Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
- This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.