TC-5820AP RF Shield Box

The TC-5820AP RF Shield Box is your ideal desk to benchtop pneumatic RF shield box. It is slightly larger than the TC-5910DPU to allow a bit more room for testing those larger wireless devices.

Request Quote Download Data Sheet

SKU: TC-5820AP Categories: , , , Tag:

Description

TC-5820AP RF Shield Box Key Benefits

  • High durability and reliable RF and noise shielding
  • Effective radiation and acoustic testing environment with RF and Acoustic Absorber
  • Specifically designed for various shapes and sizes of acoustic devices
  • Pneumatic control and operation of the lid and fixtures inside the chamber
  • Remote control by RS-232C
  • EMI filters on all data and power ports

The TC-5820AP RF Shield Box is your ideal desk to benchtop pneumatic RF shield box specifically designed for acoustic testing for your wireless audio devices. It is larger than the TC-5910DPU to allow more room for testing those larger wireless acoustic devices.

Additional information

Weight 10 kg
Dimensions 12.9 × 11.7 × 8.1 in
Function

Pneumatic

Internal Depth

15-20in

Internal Height

6-10in

Internal Width

8-12in

Manufacturer

Tescom

Specifications

TC-5820AP RF Shield Box Specifications

  • RF Shield Box Effectiveness(with I/O Module M591601A Installed): >70dB, DC ~ 3.0GHz
  • RF Connectors without module: 2 N-Type(f) Outside and SMA(f) Inside
  • Data Connectors: DB25 and DB9, RF filtered, 100 VDC, 3A Max
  • Dimensions
    • Inner Dimension: 10.7(W) x 15.5(D) x 7.8(H) inches
    • Outer Dimension: 16.4(W) x 23.7(D) x 13.1(H) inches
  • Weight without accessories: approx. 22 kg

Typical RF Shielding

Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • .1 to 2 GHz > 70 dB
  • 2 to 3 GHz > 70 dB
  • 3 to 6 GHz > 70 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.