TC-5810A Acoustic Shield Box

The TESCOM TC-5810A Acoustic Shield Box is ideal for testing your wireless audio device.

Request Quote Download Data Sheet

SKU: TC-5810A Categories: , , , Tag:

Description

TC-5810A Acoustic Shield Box Key Benefits

The TESCOM TC-5810A Acoustic Shield Box is your ideal testing tool for testing wireless audio devices. It provides high RF isolation along with high noise suppression for performing critical audio fidelity testing. No need to compromise on either isolation noise or RF as the TC-5810A Acoustic Shield Box provides all the required shielding you demand.

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

Additional information

Weight 10 kg
Dimensions 12.9 × 11.7 × 8.1 in
Function

Manual

Internal Depth

20in and greater

Internal Height

10-20in

Internal Width

12-18in

Manufacturer

Tescom

Specifications

TC-5810A RF Shield Box Specifications

  • RF Shield Box Effectiveness(with I/O Module M591601A Installed): >70dB, DC ~ 3.0GHz
  • RF Connectors without module: 2 N-Type(f) Outside and SMA(f) Inside
  • Data Connectors: DB25 and DB9, RF filtered, 100 VDC, 3A Max
  • Dimensions
    • Inner Dimension: 17.5(W) x 21.5(D) x 17.5(H) inches
    • Outer Dimension: 27.1(W) x 33.7(D) x 30.2(H) inches
  • Weight without accessories: approx. 90 kg

Typical RF Shielding

Typical RF Shielding

The shield effectiveness below is measured when the blank panel is mounted; other I/O interface panel results a different shielding effectiveness of the shield box.
  • .1 to 2 GHz > 70 dB
  • 2 to 3 GHz > 70 dB
  • 3 to 6 GHz > 70 dB

***Isolation example above is based on I/O configuration as specified above. Isolation may be higher or lower based on specific I/O configuration installed.

Custom Configurations

TC Manual RF Shield Box Custom I/O Interface Panel

Customized I/O Interface panels are available. Please contact the CTS sales team for more information

I/O InterfaceOrder NumberTypical Data Rate/Line VoltageTypical Shielding*

DB37, 1000pF pi Filter
3409-0012-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 1000pF pi Filter
3409-0009-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB25, 100pF pi Filter
3409-0014-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

DB9, 1000pF pi Filter
3409-0008-13 Mbps / 100 VDC,
5 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DB9, 100pF pi Filter
3409-0010-110 Mbps / 100 VDC,
5 Amps max
>50 dB from 0.5 to 2 GHz
>60 dB from 2 to 3 GHz
>60 dB from 3 to 6 GHz

USB 2.0 Filter
3409-0018A-3480 Mbps / 5 V, 500 mA /
Max Current: 5A
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

USB 3.0 Filter(Active)
3409-0042A-15000 Mbps / 5 V, 900 mA /
Max Current: 1.5 A
>70 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>55 dB from 3 to 6 GHz

RJ-45 Filter
3409-0022A1 Gbit/s Copper-Line
Ethernet (1000 BASE-T)
>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

DC Power Adaptor
3406-0004A50 VDC,
3 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

DC Power Adaptor,
Banana Jack Type
3406-0005A
3406-0006A
50 VDC,
10 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

AC Power Adaptor
3103-0009A250 VAC,
7 Amps max
>70 dB from 0.5 to 2 GHz
>80 dB from 2 to 3 GHz
>80 dB from 3 to 6 GHz

RF, N-SMA Connector
3408-0038>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

RF, SMA-SMA Connector
3408-0039>60 dB from 0.5 to 2 GHz
>70 dB from 2 to 3 GHz
>70 dB from 3 to 6 GHz

*SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

  • Each shielding effectiveness is measured when each I/O interface panel, which is shown above, is mounted.
  • Above data was measured by Tescom, The Shielding Effectiveness might be different based on the measuring method and condition.
  • This data has been measured under the condition that the cables are not connected to each filters. When the cables are connected it can affect the shielding performance.